Interface of serial I/O
RS232: TxD, RxD for data stream, no flow control
RS232 (RTS/CTS): TxD, RxD for data stream, RTS/CTS for
flow control
RS232 (RTS/CTS, DTR/DSR): TxD, RxD for data stream,
RTS/CTS for flow control. DTR for socket status, DSR for socket
open/close control
RS485 (Half duplex): Half duplex RS-485 interface
RS422 (Full duplex): Full duplex RS-422 interface
□
□
□
Packet mode of serial input
Packet mode could be in enabled/disabled mode. If packet mode is
enabled, the data input from UART will be deferred until the input buffer is
full, or the converter detects a 10-character packet gap and no more
character arrived. The block waiting time is extended to avoid the splitting
of the complete packet.
□
□
□
Device ID
User assigned ID number for the converter. Available ID is “0 ~ 65535”.
□
□
□
Report device ID when connected
In TCP mode, if this parameter is enabled, every time when the socket is
connected, EX-9132 Series TCP/IP converter will immediately report its
device ID in the following formats:
Serial #1 nnnnnA[LF][CR]
Serial #2 nnnnnB[LF][CR]
Digital I/O nnnnnC[LF][CR]
The total length is 8 bytes, where “nnnnn” is a 5-digit device ID assigned
by the user; [LF] is decimal 10; [CR] is decimal 13.